Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why celling fan
rotates in
anticlockwise
direction and
table fan in
clockwise
direction ? Give
technical reason.

Answer Posted / sathish

In earlier days, the ceiling fan is very heavy and down rod pipe is connected with fan through threaded coupling and chuck nuts. When the ceiling fan starts rotating in anti clock wise direction the armature winding part take jerk in clock wise direction. This clock wise movement helps to prevent the joint getting loosen. Hence the ceiling fan designed to rotate in anti clock wise direction.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is kvarh? Please define it With calculation General motors ?

1099


Bimetal strip used in overload relay what is that,which types of material used for that & percentage.

2145


why we are not giving the zone 1 trip command to the master trip relay

1678


How to design harmonic filter at the project stage without nowing the harmonics levels

2169


We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?

2041


Which thing is maximum in RLC circuit at resonance a)power consumption b)inductive current c)capacitive voltage

1739


What is notching in dc machine?

1950


List of equipments required foe industrial repair lab.

1849


how to compute kAIC?  with formulas...

4178


how to find ratio of CT & PT in 66/11kv 12 mva supply system ? explain with calculation.

2342


How to calculate cable rating for 3 phase supply?

2120


thyristor controlled APFC panel design parameter?

1733


why three phase capacitor takes unbalanced current in capacitor bank?

1430


how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2152


In DC generator, we use commutator, having no. of segments. Then how it is possible to get a half wave of voltage and current for half rotation of armature?

1947