any body tell me ,contol valve has how many cheractristic?
explain it.
Answer Posted / faiyaz
1.Linear
2.Equal percentage
3.Quick opening
4.Square root
5.Hyperbolic
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is the difference between ff transmitter and non ff transmitter
Hi i am aneesh, done btech in applied electronics & instrumentatiin. And then i took mba in finance & marketing.After that i got placement in finance co and worked there for 3.5 yrs.Now i wanted to come back to engineering job.But without engg experience, i may not able to find an opening.i have done a course related to flow meters and ite calibrations. Kindly suggest where should i try to get a job?
Explain an adaptive / self-tuning controller’s major draw card.
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
What is sensitivity in vibration probes..?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
How to check vortex flow meter is in good condition while we do not having calibration setup?
With N nodes and B branches what will have a network ???
What is zener diode? What is voltage regulator?
in differential pressure transmitter,min&max pressure range for hp&lp
can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).
what is the procedure for auto tune in masoneialn 12300 series displacer type transmitter?
For what reason would you possibly be compelled to make use of a Smith Predictor. Explain the idea behind the operation of this device.
give me all the details about the interview and which type of question being asked
in sulfur process what is material of impulse line we use to connect with transmitter ? and does teflon affected by sulfur?