11kv has three live wires how much voltage is in its single
wire(leaving the other two wires)
Answer Posted / b r rajbhar
Its depend on connection mean star or delta connection if star connection to 11kv/1.732 and delta connection same voltage of 3wire 11kv.
Is This Answer Correct ? | 4 Yes | 2 No |
Post New Answer View All Answers
What is the de rating factor of cable? What is the importance of the de rating factor in cable selection?
(1)Can earth and be conected together (2) what is the diferent between earth & neutral
Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.
sir i have cleared the apti test of EIL held on 15th march and my interview will be in new delhi on 2nd june.i will be very much helpful if u help me regarding the type of interview questions comes at EIL.(URGENT.........PLZZZZZZZZZZ...............)
we all know voltage is a force(emf), and the force always devides if 2 or more than2 loads are there but why does the voltage remains same is parallel, it must devide na ???
can any tell me why slope 40% and 80% is calculated in differential protection?
how to select the mpcbs and contactor for 3 phase 30 hp star delta motors.for plc control.and tell me the calaculation for future use.
The inventer is a battery, but if lost current at home u will turn on the fan but the is AC and inventer battery is dc . Then how the fan was rotating. What device Or machine in fan converst the Dc power to Ac power
why do you add the load short circuit impedance when considering short circuit amperage. It seems that you should only consider supply. If you need to consider loads and you don't know what loads are to be added , what would be a good sub-transient reactance rating for the loads?
What happens to a line-frequency of high-frequency transformer when it is first energized/ re-energize?
star delta starter contorl circuit... drawing..
HOW DO I CALCULATE THE SETTINGS FOR THE DIFFERENTIAL PROTECTION OF A 12kV/6.6kV, 6MVA,DYN11 XMER WITH PRIMARY SIDE CTR 400/1 AND SEC SIDE CTR 600/1?
Difference between megger test equipment and contact resistance meter test instruments?
how can we select the type of wire.what factors we have to look on it , do we have some formula to calculate it. please guide me on it
Cables Construction hi friends, 0.6/1/1.2 kV LV , DC and Control cables are concentric copper conductor what does its means and what is the use of concentric copper conductor,and are this with copper tape shield or copper screening, ? thanks