Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

By seeing a Power house Can we justify the kV of that power house?

Answer Posted / panipat

By counting insulator disc no. On ht side of transformer, ee can assume the capacity of power house. 1 disk=11kv.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much

2072


what is the basic use of power plant in equipment

1844


How We Calibrate the vaccum transmitter?

2022


DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

1051


Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.

3472


LAPT working in alternator / generator

3696


why airtel use + 24 volts and other operators use -48 volt

2700


operation

1968


What is difference between secondary Air & Tertiary Air and Their use.?

2067


why is the in steam turbine axial displacement of active side thrust pad is positive and non active side thrust pad is negative.

3315


By any way can we increase the B check hours from 300 to 500

2257


our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....

1764


what is the difference between compensated & normal drum level in boiler drum?

1860


What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?

2484


We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?

1976