Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why the no.of slots in stator in not equal to the no. of
stator in rotor in induction motor????

Answer Posted / gundra chakrababu

if the stator and rotor have same umber of poles,the harmonics produced in them are also of the same order.as these harmonics slip past each other, pulsating torques are produced,if the speed of these harmonics coincide,the stator & rotor poles would lock each other.this condition is called "cogging".under this condition,the motor would crawl at a subsynchronous speed and develops a synchronous torque.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2421


Why air circuit breaker off due to power failure?

1136


how to calculte capacitor range for single phase induction motors??pls tel

2075


if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.

1545


As an electrical engineer what are the responsibilities which i can hold in TCS?

2152


Why does curving the pole faces in a dc machine contributes to a smoother dc output voltage from it?

1192


Why is the frequency not changed during transformation of electrical energy in a transformer?

1324


What is the rotor frequency of 10 Hp 1440 RPM 50HZ 415V ?

1877


my UPS suddenly goes off and all panel light also blow off.This happens even main electric supply is not interrupted.After some time it automatically starts functioning normally.Batteries are new.

1998


What's the difference between non break power supply and non break non short break power supply

1398


why on delay timer used for fully automatic star delta starter?

1629


What is Delta Connection? What is meant by Forward Delta & Reverse Delta & How Will be the Connection in Power Transformers?

2215


What is the function of RCBO? What are the different sensitivity ratings & each application?

2756


how to control the speed to switched reluctance motor

1888


block diagram of 2 ups system connected in hot stand by mode?

8006