Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why the generating voltage in India is 11kV or why is it be
transmitted as multiples of 11

Answer Posted / vivek

No. Form Factor has nothing to do here. It is not a reason.

I answered this question on Quora. Follow up this link

https://www.quora.com/Why-are-electricity-in-forms-of-11kV-22kV-33kV-66kV-and-132kV-transmitted-in-India/answer/Vivek-Choubey-5?share=1d731487&srid=jZ2t

This provides the actual reason.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How is efficiency of DG set calculated? At many places I found the efficiency to be mentioned in percentage. But at some other places I found kWH/ litres. I want to know how dimensionless percentage value is arrived at?

1911


What happens when two positively charged material is placed together?

1135


What is marx circuit?

1119


how could we know the size of cable by physical view?

1619


Following test should be conducted to find out relative polarity of transformenr terminals A no load test B back to back test C phasing out test D none of above

2212


I have one ct of ratio 3000-2000/1 Amp its knee point voltage mentioned on name plate is 500-333/30mA-50mA at Vk/2. in secondary box there is three terminal named 1S1, 1S2, 1S3 then on which terminal obtained the knee point voltage ie 1S1-1S2 OR 1S1-1S3 & also specify the knee point voltage for the ratio 3000 from name plate.

2436


Load transfer in 11kv double busbar switchgear - operation.

1947


Discribe type of fault in DOL and stardelta startor.

2230


Define phase cross over?

1132


which VFD is better ( LT or HT)

2055


What is the basic principle of welding process?

2142


If Neutral Grounding Resistor (GR) failed/shorted. Is it repairable.

1616


in what type of applications v can use q meter?

2124


What type interview questions ask in Electrical technicians

1774


what is calculation mathod/formaulla for deciding Size of busbar (Copper/ aluminum)for L.T. panel on Various Fault level like 50kA,25kA,10kA

2793