why field resistance is higher than armature resistance in
dc machines? and why filed resistance is kept at min value
at starting in same time of armature resistance at max value?
Answer Posted / sai
To allow the maximum current through the armature, resistance is kept to very low value. According to ohm's law, V=IR.
As R is very low then current becomes maximum.
| Is This Answer Correct ? | 21 Yes | 10 No |
Post New Answer View All Answers
the winding of Generator and Motor is star or in delta ? and why
what is harmonics? what are the factors it will depend upon
What is the classification of hydro projects based on installed capacity?
33kv substation lay out details & line to line & line to earth measurements
what is star delta starter? how it works? give its control and power diagram.
solar inverters was not connected to the nuteral link .this nutwral possible to any other systems
Show Details FROM:Muhammed Ikram TO:qa@allinterview.com Message flagged Saturday, June 4, 2011 10:07 PMMessage bodyHello all, i want to ask a question to all of you that what is VMM (voltage monitoring module )? how it work,s? i heard somewhere that it compare 1 phase voltage to other phase voltage. but there is also some setting on it. how to set it,s setting. please tell me briefly. Thank,s and Regard,s. Muhammed Ikram.
State kirchoff current law?
what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero
How to do maintenance of transformer feeder.
why does connected a indutor with mnsformeretering core of current transformer ?
A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?
SUTIABLE FOR ohm's law super conductor
LT cable fault chaecking equipment and to find out the distance at what distence it failure . Name and where it is available?
witch pump used in wtp