Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is lead lag compensator and for wat v using that???

Answer Posted / prabudas

Compensator is used to compensate the deficiency in the performance of plant.
A lead compensator is used to improve the transient response and the steady state response is partially improved.
A lag compensator is used to improve the steady state response and the transient response is partially improved.
If we need a better transient response we should choose lead compensator.
If we need a better steady state response we should choose lag compensator.
If we need both transient response and steady state response we should choose lead lag compensator.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

a flow transmitter [range-0-400mbar] connected in process line. please explain me how to calibrate the flow transmitter , & how to do static error

2283


Why thermo wells are used? What materials are used in thermo wells?

1119


How many types of sensor

1620


what are the selections available in configuring a burnout protection of a controller? thanks

1974


why we are using digital signals for I/O & how to measure this signals is getting or not ?

1995


please can any one tell me clearly about pid tuning i am confusing about this .how to tune pid easly?

2247


What is the difference between mmwc and mmwg?

1382


find the kp ki kd from the transper function G(S)=29.44s+04707/1.5349s2+s

1939


Sir, I am working as a Instrument Engineer in Grasim Industries. Can any body provide question answer for interview purpose

2262


Why rdt and thermocouple both give different output .and one things more, how to generate  ohm or mili volt  plz mail me merajalam143545@yahoo.com

2813


Sir, I want junior executive, Instrumentation question papaer for IOCL, Plz send to arabinda.ghosh83@gmail.com

2312


what is the process to make control schematic ?

2251


How is automatic reference junction compensation carried out in temperature recorders?

1099


What are different types of valves?

1336


how 3 out of 2 Logic/interlocks works? give brief explanation with help of diagram.

2311