Answer Posted / dhanush d
In a 3 phase induction motor,the magnitude of the induced emf depends on the value of the slip.
At start a large emf is induced in the rotor circuit
Stator consequently draws a large start starting current which is 5 to 8 times the load value.
This may damage the motor as well as the components in line with it
Therefore,a Starter not only limits the starting current but also provides protection against low voltage and high load condition.
At the beginning the 6 ends of the three phase windings are brought out and connected as Star connection this reduces the voltage in each phase by 1 /√3 times the value it would,if it was in delta connection.
And tge starting current reduces to 1/3 of its value.
but the torque also reduces.
As this method is cheap, its used in mixers abd drills.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How to select the earthing transformer,for DELTA TO DELTA TRANSFORMER OR ALTERNATOR SIDE.Pls post your answers and calculation.
what's the difference between abs/inc encoders. apart from the position remembrance what are all the other differences. and what's mean by grey code.
What is grid collapse? what is the reason for it?
What is mean 2XWY
What are the basic properties of signal flow graph?
What is the tipical Online UPS input voltage for 20 KVA load ( 3 Phase or 1 Phase )? Why ? Explain it...?
what is the transmission loss for electrical supply? specifically a large shopping complex where the grid is half KM away, what will the % of transmission loss? is there any transmission loss for captive unit generation for above set? thanks
What should be the values of settling time, peak time, steady state error, overshoot, rise time, MPOS (Maximum percent over shoot) to keep the system in transient state, to keep the system in steady state ?
Use of switch mode power converter in real-time basis?
How can find thermal state value in relay for calculate thermal overload.
If a surge divertor is required to be protected by 32 amp C Curve Circuit breaker does this limit the amount of protection from surges that you will acheive
What was your role in the silicon evaluation/product ramp? What tools did you use?
with 3 phase board on a 63 amp rcd is it ok to have 6 electrical showers 2 on each phase and what problems could happen
Formulae for calculating the transmission line losses for different voltage levels
When will you multiply and devide with derating factors to the actual value while sizing the cable?