what is difference between pressure,flow and level control
valve.
Answer Posted / samir
The Control valves is used for auto loop control of pressure, flow and level. So if we use it's a pressure control valve then desired set point should be pressure of the system. Similarly for LCV & flow control set point is Level & flow respectively. Here should be consider one thing the same CV can't used in three application as because of others parameters are varied to system wise.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
steps for installing orifice plate?
what are the values of fuel flow rate in various places in boiler.
hey any one got the papers of SAIL and HPCL plz do help me by posting them to my mail ID's naren07_87@yaho.co.in, surenarendra@gmail.com
what is the imbustion control loop
Hi i am aneesh, done btech in applied electronics & instrumentatiin. And then i took mba in finance & marketing.After that i got placement in finance co and worked there for 3.5 yrs.Now i wanted to come back to engineering job.But without engg experience, i may not able to find an opening.i have done a course related to flow meters and ite calibrations. Kindly suggest where should i try to get a job?
In my company plc based winders are operated. one day there was a data transmission failure alarm shown on pc. as per sir instruction we have reset master plc but winders were not triped and alarm gone. so what master plc do?
Why trim span ? How?
Galvanizing.
why we use impulse line of flow transmitter at 45 deg. angle both side of orifice plate.
I am manjunath having exp in maintenance of chemical plants,know i want to do a design course INTOOLS,after doing design course can we get jobs in design field.sinve i dont have design exp..
PT RTD Range: -200 to 500 degree celsius If I configured in DCS Lower range and Upper range . In face plate it shows red colour due to overa range how was the characteristics look If the temperature is more than operating range. how was the characteristics look . whether its in Resistance vs Temperature curve is Linear or Non linear
WHAT IS THE CAM POSITION IN CONTROL VALVE POSITIONER ? WHY IT IS USED?
can we copy the software from a transmitter using hht(hart 275) ?
A flange is used for instrument connection for a system with a design temperature of 316C (600F) and a design pressure of 1000 kPa (145 psi). What is the class rating of the flange to be used for this application? Explain your answer
How to check vortex flow meter is in good condition while we do not having calibration setup?