Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the function of end capped column?

Answer Posted / vinod kumar uppalli

The SI-OH functional groups tend to ionize at at higher pH into negatively charged group. This will lead to secondary interaction between Si-O negative and basic analytes. This leads to tailing of peak, to overcome from this issue columns are end capped.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if your product is soluble in 0.1n hcl and water then which you choose as media from these 2 media?

686


can we use the same detector in HPLC as well GC and what could be the differences we can find in the final chromato graph in any aspects?

2188


In IR spectra, generally a molecule vibrates without apply emr or ir light?

1985


What is the formula for relative diffrence for standard solution in solution stability in validation?

810


why require the ph, buffer during hplc mobile phase?

868


Related substance method equivalency on control sample or spiked sample?

777


In the HPLC Calibration done wavelength accuracy done between 200nm-280nm .but not done remaining 300-400nm not done ?

928


how a particular wavelength can be different for a particular compund while analysing by uv and by HPLC.

2309


why we are using hexane in calibration of number of drop per mL

1741


what is %labelled amount in content uniformity of dosage unit and its calculation?

5241


In which situation we require to prepare the standard solution from sample in Related substance method?

785


What is the difference between Discriminating media and DPDM(Dissolution Profile with Different Media)

7550


acceptance criteria for lod & loq by standard deviation of response and slope??

2596


Is it nessesary all multimedia dissolution require descriminatory?

801


Which parameters require to do in tech transfer?

761