NATURAL GAS ENGINEERING - QUESTION 26.1 : (a) In natural gas pipe sizing, the length of the pipe from the gas source metre to the farthest appliances is 60 feet. The maximum capacities for typical metallic pipes of 60 feet in length are : 66 cubic feet per hour for pipe size of 0.5 inches; 138 cubic feet per hour for pipe size of 0.75 inches; 260 cubic feet per hour for pipe size of 1 inch. By using the longest run method : (i) Find the best pipe size needed for the capacity of 75 cubic feet per hour. (ii) Estimate the suitable range of capacities for the pipe size of 1 inch. (b) The maximum capacities for typical metallic pipes of 50 feet in length are : 73 cubic feet per hour for pipe size of 0.5 inches; 151 cubic feet per hour for pipe size of 0.75 inches; 285 cubic feet per hour for pipe size of 1 inch. By using the branch method find the best pipe size needed for the capacity of 75 cubic feet per hour when the length of the pipe from the gas source metre to the appliance is 52 feet.

Answer Posted / kangchuentat

NATURAL GAS ENGINEERING - ANSWER 26.1 : (a)(i) Best pipe size needed = 0.75 inches for the capacity of 75 cubic feet per hour. Data for a metallic pipe of 60 feet in length and maximum capacity of 138 cubic feet per hour instead of 66 cubic feet per hour are selected. (ii) Range is more than 138 but less than or equal to 260 cubic feet per hour for pipe size of 1 inch. (b) Best pipe size needed = 0.75 inches for the capacity of 75 cubic feet per hour. Data for a metallic pipe of 60 feet in length instead of 50 feet and maximum capacity of 138 cubic feet per hour instead of 66 cubic feet per hour are selected. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is pneumatic conveying?

717


Define a surfactant?

593


What significance the angle of repose holds in the chemical industry, explain?

643


have any one question paper of institute of plasma research center for aptitute as well as technical?

6493


What type of flow measurement devices is best for slurries?

637






Why is post-weld heat treatment sometimes necessary for welded vessels?

2081


What is the ignition temp. of Alluminium,Coper&Iron.

1815


i want to knowwhat kind of questions in interview in adnoc?

1635


testing formula for oxygen by ammonium chloride,ammonium hydroxide and copper

560


What are some guidelines for designing for liquid and gas velocities in process plant piping?

643


What is the wet bulb globe temperature (wbgt)?

643


What are the different types of equipments for the conveyance of solids?

572


What is fuel requirement of 20kg/hr of incineration having material calorific value 6500 kcal/kg and diesel calorific value 10707 Kcal/Kg (PCC=850 degC and SCC 1050 Deg c)

1255


What is the order of a chemical reaction, , if the rate of formation of 'C', increases by a factor of 2.82 on doubling the concentration of 'A' and increases by a factor of 9 on trebling the concentration of 'B'?

3186


Explain how can one estimate how the friction factor changes in heat exchanger tubes with a change in temperature?

674