What is reheater protection based on what mft will be act on RH protection
Answer Posted / venkatesh muthi
When boiler is working and sending steam to turbine,if there is no path for steam flow.then to boiler drum pressure increases to avoid that.we use reheater protection.like if both hp stop valves closed and hpbypass valves closed or both ip stop valves and lpbypass valves closed(when it is aft synch). And before synch condition is if both hpbypass and lpbypass valves closed.if both ip stop valves and lpbypass is closed then there is no steam flow from boiler reheater leading to increase in pressure at reaheter and temp also increases as continuous heating.so it is called reheater protection.to protect reheater
Is This Answer Correct ? | 4 Yes | 12 No |
Post New Answer View All Answers
what is the trip circuit supervision in an electrical meaning?
What is difference between secondary Air & Tertiary Air and Their use.?
can dp type level transmitter work in under vaccum condition
why airtel use + 24 volts and other operators use -48 volt
How do you consider that you can improve and what assistance do you need to achieve this
how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?
why do you consider yourself a suitable candidate for this position
How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.
our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much
can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?
LAPT working in alternator / generator
some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor