Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why do u get different drug release while doing calibration
of dissolution test appratus 1& 2(paddle & basket)?

Answer Posted / sachin

When we calibrate with paddle at prescribed time it gives less release compare to basket release due to surface attachement of tablet or contact area of tablet.

Is This Answer Correct ?    7 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

While performing TOC sst analysis Zero shift disabled & sample analysis zero shift enabled why?

2848


why sre you used Potassium hydrogen phthalate in standarisation of 1N NaOH and 0.1 N Perchloric Acid?

9783


all types of questions asked at the cipla interview

4674


what you do when compound having dwel wavelength?

737


what is the purge flow & how to calculate

2634


Why only 1.2 million lux hours require in photostability study?

1020


How will u perform degradation study in detectors other thann PDA in HPLC Methodology

2533


Why we select scan range from higer wavelength to lower wavelength in uv visible spectroscopy and ftir spectroscopy ? .

902


in dissolution why pool sample needed? in which type of drug pool sample need?

3170


if instrument calibration fails then what require to do?

972


why should we perform dissolution PVT calibration only by UV spectrometer, not by HPLC ?

1701


If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?

767


mode of absorption in alimentary canal?

2384


What is the acceptance criteria for moisture balance when calibrated with sodium sulfate

2032


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

844