I have a 33 KV sub stn with two mother transformers 33/11
KV of capacity 3150 and 1600 KVA respectively. The total
connected load 16809 KVA(11/0.433KV).how i calculate the
max current & how i decided the CMD.

Answer Posted / er.mazhar0731

CMD 12.85 MW
Maximum current 675 amp

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.

1574


3Cx240 & 3Cx300 sqmm Al. cable from lv side. What is the calculation for this cable??

898


During FEED, you will have all the information with regards to cable. How will you calculate the MTO for MV and LV Cables? what are your considerations?

2040


Logic using 1 kV or 1,1 kV grade in house wiring Low voltage cable. Explain/suggest? some use 1kV and some prefer 1.1kV grade insulation low voltage cable why??

1227


1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?

1772






What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?

1564


Write the force balance equation of ideal dashpot element.

850


what is the function of bearing in dc mchine" and where it is placed

2079


What type of pipe material G.I or M.S is used for sprinkler system?

8343


Is there any reason that we get shock on touching phase wire because the earth is at neutral potential? Is there any reason that the earth is at neutral potential because the neutral is earthed in apower station

1558


what is the difference between online & offline caliberation of KWH meters. Can Digital meters be caliberated

1524


What are m circles?

667


In ups static switch if i gives the supply at output end it will open the circuit in stactic switch or not if it will open then how it operates.

1855


which type of amplifiers are used in multimete?

1651


which are the criterias needed to select the kind of neutral earthing(solid earthing,resistance earthing,etc.) at various voltage levels in electrical distribution?

1510