Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is difference between Dy11 & Dyn11 vector group
transformer. Can both these transformers operate in
parrallel.

Answer Posted / jim kirk

Mr Ravi

An excellent explanation - but there are DY11 transformers - we have two of them onsite

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

which pump used in STP

2221


Plz tell me how we can find that particular company has vacancy or not

2272


What are locations arc protection relay is fixed.

1882


why we use circuit breakers for switching instead of normal switching device?

1876


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The slip when motor stalls is A 1 B 0 C 13.33% D 10.33%

1936


Distribution transformer we provided 2 separate earthing pit for Body and 2 separate earthing pit for neutral,we can not connect separate body earthing pit to other earthing pit but we do metal glanding in secondary side cable termination in both side, transformer and PCC panel (LT Panel), is this safe for transformer and other equipment?

1723


how we test a 3 phase motor on single phase supply....? HOW WE RUN A 3 PHASE MOTOR ON SNIGLE PHASE. supply for testing..? how we verify of a 3 phase motors 6 wire & name thame a1/a2/a3..b1/b2/b3 and c1/c2/c3 for connecting star delta starter ........i have only 1 phase supply ? help forum..........

5198


please send me last 5 year interview questions

2196


what is the ms flat constant for calculating earth mat design calculation?

2516


Why let through energy not considered for ACB breaker while cable sizing?

2415


what is thermal resistance of PVC Cable.

1805


On Which Pressure PRV is operated.

1726


Explain Even and Odd signals?

1907


The electromagnetic torque developed is proportional to what in a D.C series motor?

1172


Grid fault level [KA]?

2611