CHEMICAL ENERGY BALANCE - EXAMPLE 11.2 : Calculate the cooling duty, H required to condense and cool acetone from 100 degree Celsius to 25 degree Celsius at atmospheric pressure. The heat of vaporization for acetone at its normal boiling point is 30.2 kJ / mol. The boiling point of acetone at atmospheric pressure is 56 degree Celsius. The flowrate of acetone through the condenser is 100 mol / s = N. Value of sensible heat needed to increase the temperature of acetone in liquid form from 25 to 56 degree Celsius is 4.06 kJ / mol. Value of sensible heat needed to increase the temperature of acetone in vapor form from 56 to 100 degree Celsius is 3.82 kJ / mol. Unit of H is kJ / s.
Answer Posted / kangchuentat
CHEMICAL ENERGY BALANCE - ANSWER 11.2 : In the same state, total heat changes in heating = total heat changes in cooling for acetone. H = N ( total heat of sensible + heat of vaporization) = 100 (mol / s) [ (30.2) + (4.06 + 3.82) ] (kJ / mol) = 3808 kJ / s. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
which materials can l use if l want to use length wave 680 to 900 in hplc
After conducting an internet search for ways to reduce energy costs, I found a recipe for whitewashing that is said to reflect sunlight. The recipe calls for 20 pounds hydrated lime to 5 gallons water to 1-quart polyvinyl acetate. What is a good source of polyvinyl acetate that I can buy at a local store?
Explain the steps taken to operate a tank-blanketing valve?
We are having proplem with the persperation smell in ETT/ECHO room in our cardiac hospital.The 2 Ton of AC is not conditioning the environment. We have to use exhaust fan to through out of the room bad air. Could anyone suggest how to coup with this effectively using chemical engineering. Any permanent solution to neutralise the bad smell.The Air freshners are not doing enough instead making a bad odour.
List the advantages and disadvantages of a pfr?
Mention some of the specialized grinding methods?
In case of welded vessels why is stress relieving in the form of post-weld treatment necessary?
How can you determine the proper pipe thickness for a slurry line?
What is a good device to use for obtaining viscosity data for a non-newtonian fluid?
Are there any alternatives to scraping a shell and tube if a capacity increase will make the pressure drop across the exchanger too large?
What is some common piping materials used to transport slurries?
What are the merits of using a falling film evaporator?
need the type of technical questions in written test
What are the reasons of removal of particles from effluent gas?
Explain global warming from a common man's and an engineer's perspective?