Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why Power generation in India is at 50Hz while in America
its 60Hz so is there any advantage/Disadvantage of this ??

Answer Posted / sharat das, mahindra ltd.

The frequency is 60hz and 110v supply. but in india
is about 240v,50hz supply. for a particular load say 100kw
the current will be 0.416A. but in 60Hz the same load will
consume about 0.9A. here the thing is the heat produced in
the cable bcoz of the flow of current will be large in 60Hz
compare to India. since a cold country they can use
this level but not by India. And also specified for Country By WEAC Roles.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are your future plans for the company if permanently employed?

2128


what will happen reduce the transformer voltage from 415v to 406v, is it save the energy,? are this methodis good to reduce the energy.?

1487


What is the difference between isolators and electrical circuit breakers?

1140


1. What is maximum permissible distance between smoke detectors ? 2. How do we decide number of smoke detectors required in a large office, warehouse, hall etc ? 3. What should be maximum height of smoke detectors ? 4. Where do we use heat detector, optical smoke detector, temperature sensitive detector ?

2874




2369


for 11KV OH system what will be typical per KM "R" "L" "C" parameter. for 33KV OH system what will be typical per KM "R" "L" "C" parameter. for 33KV UG system what will be typical per KM "R" "L" "C" parameter.

2419


A power transformer 4MVA/11KV/0.415Kv has been out of use in 12years. what maintenance actions/test need to be carried out before energizing.

1286


How will change the frequency in distribution side?

1760


The Howland current source produces a A Unidirectional floating load current B Bidirectional single-ended load current C Unidirectional single-ended load current D Bidirectional floating load current

2059


Which material is used for the core of a transformer and why?

1073


WHAT IS VCB SAFETY

1217


What is the ratio of Booster transformer?

2136


what is the formula to calculate voltage drop/loss on 66KV Transmission Line?

3661


do you have some of interview Questions in power and genrator section in general whith answers

2164


a 230v transformer with step down ratio 19:1.it has 2000turns on primary and rated 25va calculate max primary current no of secondary turns volts/turn

1513