What are types of encoders?
Answer Posted / scot
Simple answer is two
incremental
absolute.
now from those you can expand on sensing technology (optical, magnetic, inductive, see newall.com)
Expand on mounting: shafted, hollow shaft, modular.
expand on type: rotary, linear.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
1. What is the exact formula for one weber? for example,(one ampere = one coulomb electron of electrons crossing a point of conductor at one second. i.e, 1A=1Q/1sec)
the typical output of a solar cell is........
why fractional pitch winding generally used in alternators?
Can anyone please provide me details of MCCB/Contactor/SFU rating calculations for a motor feeder..for example 50 kw.. not from type-2 cordination chart. i want manual calculations..
why star point of HT motor not earthed?
1.what is difference in maintain Hz again Hz in USA ? 2.how to calculate the battery AH? 3.why are yearly maintained in transformer how many tests in required?
Did RMU have ct and pt ?
explain the process of commutation in a dc machine. Explain what are inter-poles and why they are required in a dc machine.
What are all present producing cost of Per KWH of various Fuel?
how to build a network which step down 415v to 1v rms
IF I KNOW THE AREA OF CROSS SECTION OFTHE WIRE , WATTAGE OF THE LOAD ,VOLTAGE SUPPLY WHAT IM GIVING TO THE LOAD AND ALSO POWER FACTOR OF LOAD ....... SO GIVE ME FOR WHAT AMOUNT OF CURRENT I SHOULD USE WHICH TYPE OF CABLE?
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
i want to apper for apgenco or aptransco or related can any one sugest me where can i get previous papers of thouse exams
draw vector diagram and +ve,zero sequence diagram of symmetrical three phase fault.
What is the meaning of 40X8X2 busbar dimensions for carring load of 400 Amps