Answer Posted / faiyaz ahmad
Diaphragm convert force into pressure
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
what is the difference between profibus and controlnet networking.
Explain working principle of lvdt?
how works encoder in plc
what is the difference between -24 : +24 & 0:24 and where it use?
how do i tune dearator pr control valve using PID. we set the set point is 0.6kg/cm2 now i want 0.5 to 0.7kg/cm2 limits so what should i give p,i,d values. then pls explain how do set pid values for control valve tuning?
What is the difference bitween control net scaner and device net scaner
Im having problems with interfase betwen SPI v7.0 and SPPID v5.05. Previous versions of Intools shoul be fixed with SPPIDproj.ocx file. It was necessary to replace this file with one that allows the connection between different versions of SPPID. It is necessary in the current version to do the same?Thanks
What is the exact differences between HART,FOUNDATION FIELDBUS,PROFIBUS?
How a conductivity sensor & analyzer work at boiler, whats the principle & science is beyond this,How conductivity sensor sence & convert signal & move toward analyzer & analyzer show reading in percent? also what is temperature compensate option in conductivity analyzer
give some question relative instrument fitter?
while am calibrating Drager polytron 2IR flame gas detector occured non zero status.how can i get zero status?
where proximity sensor installed on tank in loading arm application
Identification of ss fittings, pilot valves, relief valve.
Senior engineer's please help me, what is Loop Checking and Loop test? and write difference also? soon urgent