HEAT TRANSFER - EXAMPLE 5.3 : In a cylinder with a hollow, let a is outside radius and b is the inside radius. In a steady state temperature distribution with no heat generation, the differential equation is (d / dr) (r dT / dr) = 0 where r is for radius and T is for temperature. (a) Integrate the heat equation above into T(r) in term of r. (b) At r = a, T = c; at r = b, T = d. Find the heat equation of T(r) in term of r, a, b, c, d.
Answer Posted / kangchuentat
HEAT TRANSFER - ANSWER 5.3 : Let r (dT / dr) = e, then dT / dr = e / r. T(r) = e ln r + f by integrating both sides where e and f are constants. (b) Let c = e ln a + f and d = e ln b + f. Subtracting both equations gives c - d = e (ln a - ln b) = e ln (a / b). Then e = (c - d) / [ ln (a / b) ] and f = d - e ln b. T(r) = e ln r + d - e ln b = e ln (r / b) + d = (c - d) [ ln (a / b) ] ln (r / b) + d. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what is the difference between car seal close/open valves and lock close/open valves?
How does hollow shaft impeller works? Does it based on principle of pitot tube?
testing formula for oxygen by ammonium chloride,ammonium hydroxide and copper
Can you pls tell me how to calculate the amphere rating of cable in case of three phase supply but all load is single phase
what is mass flow rate of steam of 7 kg/cm2 pressure in 1 inch id. pipe.
Oil and fat containing food items are flushed with nitrogen. Why?
What particle sizes are electrostatic precipitators used to remove?
hi can anyone tell me some technical questions asked in iocl
print a pattern of abcdcba abc cba ab ba a a ab ba abc cba abcdcba
Difference between Synthetic foaming agents V/S Protien based foaming agent?
send me previous year question paper for ongc gt 2011 written exam
Define condensate lift?
We are having proplem with the persperation smell in ETT/ECHO room in our cardiac hospital.The 2 Ton of AC is not conditioning the environment. We have to use exhaust fan to through out of the room bad air. Could anyone suggest how to coup with this effectively using chemical engineering. Any permanent solution to neutralise the bad smell.The Air freshners are not doing enough instead making a bad odour.
How 'saltation velocity' is used in designing pneumatic conveying systems?
What is the use of gear pumps in motor?