What is RTCC panel and why it is required
Answer Posted / basir
RTCC means- Remote tap changing controller
And it is used to maintain the stable output voltage of the transformer by
changing the taps because we need constant voltage.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
i want to know how to determine that a surge arrester work properly in 11kv system. and how to test a 12kv surge arrester
how to find Harmonics and types as per the equipemnts
1.how many earth pits are required for 1000 k.w plant include substion , transformer ? 2. how many earth pits are required for 500kva generator.what is formula to calcute?
What is steady state response?
what is the difference between elcb and rccb ?
Explain M Var? Which types of problem occurs when reactive power increase at the time of full load of plant and at the time of synchronize of plant?
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
What is the principle of HIGH SPEED DIRECT DRIVE MOTOR ?
How can we connect additional batteries to three phase ups? What are parameters we have to check when connecting?
why the check zone and main zone are used for Busbar Protn. scheem?
1. Can a 12v DC choke operate a 60v/12w PL lamp ? 2. Can a 230v ballast fire / operate a 60v/12w PL lamps.
Can Anyone Answer anyone of these ? Q1) why direct SOLUTION of Load Flow Studies in Not Possile ? Q2)Why majority of Buses in power system are load buses Q3)Why one of the buses in Power system is taken as reference bus (slack or swing) Bus ? Q4)Bus Admittance Matrix is a sparce (means it contains some zero elements ) matrix , give reason
700KW 6.6KV slip ring induction motor to use VFD to control the speed
what is conductor copnstant of ab cable
why transmission is only 3 phase and not 2 or 4 or poly phases