Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is meant by H.R.C fuse?

Answer Posted / avinash koila

High rupturing capacity fuse has faster operation and highly reliable. Quartz and sand is used as arc extinguishing media.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are protections for dty type transformers

1840


How to calculate no of EARTH PIT? Describe the formula as per IS standard?

2183


what is static frequency converter?what is the function...of sfc...?

2244


Explain the advantages and disadvantages of hydropower plant?

1137


we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain

2221


When MICC cables used ?

2093


There are Two questions about Steam Turbine Generator... What is HRSG bypass of LP, HP used for in power generation? In particualar, in the event that fault of HP bypass, there would be STG TRIP in operation but none on the LP bypass fault...what's the reason ?

2321


what is the use of the circle diagram

5625


What is the maximum breakdown voltage of 11KVA and 66 KVA power line and how it is calculated?

2290


how slip power recovery system work

3030


volts=230 c=10mf a=??

2045


Can we check ELCB constantly from R1 to R8 phase in 1 no DB?

1700


Application Comparison between 22KV (UE)and 33KV (E) system. Are we allowed to use 33KV (E) cable in lieu of 22KV (UE) cable. What are the technical disadvantages.

2361


What Normal(Tangent) towers and Tension(Cut-point) Towers?

6223


How will calculate losses in an multi core Aluminium LT cable of different sizes & upto what length we can use a LT Cable ?

2154