Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we are using only lead standard solution for Heavy
metals test? what is the purpose of this?

Answer Posted / sandeep

In production mostly we are using GLR and other equipments most of them come up means coating with lead so while in the reaction there is a chances of leaching of lead may takes place that is why we are using mostly lead as a std in HEAVY METALS testing...

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how can give the expiry period and restadardisation of volumetric solution

2582


how to calculate elemental impurities?

1030


if instrument calibration fails then what require to do?

972


What is the difference between chromatographic purity and related substances?

1357


How they found 1mL of K.F reagent is equivalent to 5mg of water and if we change the composition of K.F reagent, is it can neutralize more amount of water?

1764


what is diffrence between specificity and selecivity?

754


Tell me about analytical method validation in QC

6167


in DMF having extra impurities and in api COA also having extra imp than USP or BP product then how require to proceed?

818


What are the primary considerations in extractables and Leachables ?

2266


give clarity of linearity and range in method validation

2412


why cone formation during dissolution?

774


if peak get problamatic then what require to do?

792


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1858


From where require to take the RLD sample?

747


For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

1900