Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How can get electrical c licence.Now i am working in spining
Mill , transformer capacity 2750kva. Sanction demand 2250kva.
Please advise me . My contact no 09944226823

Answer Posted / vadlamudi068

dear sir ..
I completed diploma in electronics and communication engineering.how can get electrical c licence.now i am working in NTTF collage in electrical maintenance..please tell me about this..

Is This Answer Correct ?    2 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why we get 2 differnet values for power factor in 2 watt meter method in 3 phase

1854


please send me the previous year's question papers of jindal GET exams

5898


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2147


How i can calculate current of cable according to ares?

1991


why capacitive load is not used in routine life????any reason is there ??????

1754


Good morning: I'm looking for some informations about the OLTC or the LTC: I wont to know what the function of the tie-resistor in during the operation of reversing/coarse operation Cordially

1995


What is warm / cold start of HT motors. How many warm start & cold start are possible in a day?

2044


What is the capacitance values of 132,220,400 & 765 kV current transformer

1910


how to handle 2500 kva transformar

1623


Importance of fault current in power transformers and how to monitor the same? How is it different from winding temperature?

1829


Why Utility Distribution System in India is mainly at 11 kV? Why not Utility go for 33 kV?

1739


what is metering cum synchronizing panel and how it is used?

4634


How do I calculate/select Droop CT ratio for various capacity of generators?

3645


Hello everyone, somebody knows what is a "surplice power" ? The hole phrase is: "This rating is appropriate for a generator set paralleled with an infinite bus e.g. a national electrical supply network or grid where the generator set is run at 100% load, 24 hours a day, 365 days a year and any surplice power is exported into the grid" Thanks in advance.

1771


WHAT IS SHORT CIRCUIT STRENGTH OF 100 AMPS MCCB?

2113