Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the rating of your capacitor bank at your company.

Answer Posted / vinesh

Power factor is only present in the ac power supply systems. In dc there is no usage of power factor terms. Ac supply is having frequency and potential is alternating with respective to time as such the load on the ac power source is of mix like capacitance, resistance and inductance

Capacitance is offered by ug cables and heater and filament lamps offer the resistive loads and hid and fluorescent lamps offers inductance value

Inductive reactance (xl) and capacitive reactance (xc) is counter each other and resultant effect will reflect in ac system in addition to normal resistance. This cumulative resistive effect is called as impedence.

Now power factor is equel to pf = r/z.

Now if we draw a power circle the you know the differnce of kw and kva is made by kvar that is reactive power if we reduce this reactive power then the kva demand and kw i mean apparent power and actual power will became more or less equal. Now power factor that is quality power.

So we can improve the power systems by adding counter reactive power by adding capacitors in kvar ratings.

Apfc panels are best suitable for proper monitoring as static correction will not perform well in massive load centres as failure and degradation of capacitor is hard to find out and rectify.

Is This Answer Correct ?    6 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

FEINGING DECREASES THE FLUX DENSITY IN THE AIR GAP. HOW?

2191


plz send me HPCL apptitude paper.. maulik_elect@yahoo.co.in

2084


which pump used in STP

2221


The loads are connected with phase and ground then why current flow as the loads ?

1967


Can we check ELCB constantly from R1 to R8 phase in 1 no DB?

1699


Why do we use copper cable for HT Supply and why not Aluminium?

2009


how to put cable sizing and cable glands size for respective cable & Cable Lug size in a DB sectors???

2170


we have two motors 1250kW,6.6kV to be coupled on the same shaft ,so please provide assistance for their synchronisation.

2066


If we have 11 kv RYB Phase single core cable near about. Then wht effect and losses

1875


determine two methods to find loose connection in operational electrical system?

1685


percetans

2190


lenz law application and define

2837


What's mean HVF & HAF in Vacuum Circuit Breaker?

5352


how is calculated the quantity of weight in hot test xlpe?

2514


how to calculate energy of 3-phase motor?

2079