Answer Posted / msk
Bus coupler is a device one side to another side power supply producing purpose.because any one EB incomer will be failure it will be power supply to the feeder.and eqiupement safety .
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
can i use 4 number of circuit breaker as single phase manual change over switch? if yes then how plz also send ckt diagram at nazimzamurad@gmail.com
How will you define capacitance?
what is the difference b/w pvc cu conductor and cu breaded wire..?
What is the difference between type1 and type2 relay protection co-ordination for motor feeders
What is the Resposiblity of Electrical Utility Engineer
block diagram of 2 ups system connected in parallel mode?
whats the differece between Exd and Exe
what is formula for zero phase sequence of nuetal earthing transformer of 6.6 kv
What are two contours of nichols chart?
in the directional overcurrent and earthfault protection,normally we are setting the angle 45 deg lead for phase fault overcurrent and -45 deg lead for earthfault fro forward direction.but both the fault are operating on the same angle region only.why?how the relay will response?
in Contactor opearation Why there is a difference in the values of the operate and release voltage in case AC supply
what do w do when the output of generator is fluctuating?
how many joints are allowed in underground HT cable of 1 KM
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
Electromagnetic torque developed by the motor is compared to shaft torque. A less B same C depends on motor design D more