if drum level is low what is interlock? i mean we put
interlock to fd fan or id fan ?
Answer Posted / dilip jha
If drum level is low , firstly ID fan will trip then FD fan tripped then PA fan will Tripped.
This is the interlock of Drum Level Low.
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
what about your moleg in pogrees with company
what is the different between deflection type measurement and null type measurement in RTD?
Operational amplifiers
What are different type of instrument cable
Explain PID controller tuning & any one method used for it.
give some question relative instrument fitter?
Difference between ultra sonic flow meter
please send the sample qustion paper for iocl written test ..
any body who gone thru recent iocl interview.INSTRUMENTATION questions. I need.
what is your eligibility criteria for freashers?
Pressure tx shows 1 mbar but we need 1000 mbar at this process condition .. how can we sort it out .
Regarding , there is an air cooler which control the fans(50% of AV FANS) by temperature in outlet , and the louver of Air cooler is controlled by HIC from control system , So if on Air cooler we will consider 2 individual I/P converter or positioner?
I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
Turbidity analyzer working principle ?