what is the difference between concentrated winding and
Distributed winding in motor?
Answer Posted / davod habibinia
Concentrated winding in 3 phase armature means that the value of distribution factor (kd in many references) be equal to 1. It means that the winding is concentrated along a pole.
In distributed winding the value of kd in the base winding (machine period) is below 1, which determines that the value of the induced EMF in one phase is less than the value of "induced EMF in one coil * number of coils series in one phase" .
With this definition the only winding in 3 phase anrmature which have concentrated winding is the machine having q=1 (q is the number of slot per pole per phase) .
Then there is machines which has the winding with one slot pitch (q=0.4), but illegally said to have concentrated winding but actually the winding is distributed with kd=0.9659 and kp=0.9659 and therefore kw=kd*kp=0.933. (Kp is pitch factor) . The value of winding factor (kw) could be determined with star diagram of winding, and pitch factor too, then we can see that the kd will be lower than one for this machine (q=0.4).
These type of machines which has one slot pitch for the each coil of their winding are called "tooth wound machines" and not concentrated.
Is This Answer Correct ? | 5 Yes | 1 No |
Post New Answer View All Answers
what the principle of sincroscope?how it works?when it needed?
what is the voltages using in movie theaters??? why ??why not other??
is that a problem if i connect a single phase load to a secondry delta connected transformer but i get a neutral from other transformer i the system?
What does the term power factor shows?
plz send me the placement interview question and answers of whizchip(technical and apttitude)..i have an interview in next.
What do you understand by external characteristics of a d.c. Generator?
how to conduct dc resistance test for rotor of an alternator and how to measure the rotor dc resistance value theoritically?
In a flange coupling, the flange bolts are designed for
What is the slip speed?
What is difference between safe PLC and normal PLC
What is evaporator & condencer & compressor
what is differnce btwen lll and lllg faults
What is cable tray, its type, and its support?
If 100 KAV USP dedicated earth got disconnect / Cut. What will happen at load.
Please brief working principle & construction of permanent magnet AC Servo motor