Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Formula of Potency calculation on Dried basis, As is basis& Anhydrous basis.

Answer Posted / sandip pawar

Potency(as is basis)=100-(Total impurities by HPLC+residual solvents+water content/LOD+sulphated ash)

Is This Answer Correct ?    38 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if instrument calibration fails then what require to do?

891


For titration in anhydrous media with perchloric acide, if lack of titrator, Which indicator is been used for replacement. How calculate pH of test solution to choose suitable indicator?

2262


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3117


In the HPLC Calibration done wavelength accuracy done between 200nm-280nm .but not done remaining 300-400nm not done ?

857


Why only hydroxy naphthol blue indicator is used for standardisation of 0.05M EDTA solution instead of solochrome Black T or Euriochrome Black T indicator which is used for all sample analysis with 0.05M EDTA solution?

2665


what is the procedure for cleaning of lenses of hatr accesory of ftir instrument?

2227


What are the primary considerations in extractables and Leachables ?

2213


acceptance criteria for lod & loq by standard deviation of response and slope??

2531


UV and PDA detector, which have less signal to noise ratio?

1081


How can we calculate offset value pH measurment

1461


How to compare XRD graphs against standard and carry polymorpism study of API's by powder XRD method?

3818


which one is better separation in high pressure liquide chromatogram orlowpressure chromato gram in hplc

2117


In BP2013, Loperamid HCl monograph. Assay by titration with 0.1N sodium hydroxide using hydrocloric acid 0.01N and reading the volume added between the 2 points of inflexion. I have a question that if the diluent solvent is ethanol is certainly consumed a amount of volume of titrant, so this volume must be eliminated on the result calculation or not apart from first point which is subtracted above.

3065


Why to use propyl paraben in HPLC gradient calibration

7315


how require to interprit the method precision data of hptlc?

759