Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is GIS (Gas Insulated Switchgear)

Answer Posted / hanupowergrid

It is very much required to establish an electrical substation at load center. Since, establishing a substation at load center is quite economical and profitable in many aspects. As it reduces length of feeders and due to short length feeders, the quality of voltage regulation improves. But the main obstruction of establishing a substation at load center is space. Generally main load center of any place is situated at very congested place where, sufficient land for establishing conventional electrical substation is very hardly available.

his problem can be solved by using gas insulated switchgear technology. In this type of switchgear, all the necessary components of switchgear can be assembled in very limited space. GIS is a kind of metal enclosed switchgear. That means, all the equipments of the electrical switchgear are enclosed by gas tight metal enclosure and SF6 gas is used as insulation between live parts of the equipments and earthed metal enclosure. This type of switchgear, means, gas insulated switchgear is available from 12 KV system to 800 KV system. For establishing electrical substation in very limited place this type of SF6 insulated electrical switchgear plays the major role.

Gas insulated components of substation are generally,

Electrical bus bars.

Electrical isolators or disconnectors.

Circuit breakers.

Current transformers.

Voltage transformers.

Earth switches.

Surge arrestors or lightning arresters.

The substation, assembled by gas insulated switchgear, is popularly known as gas insulated metal enclosed substation (GIMES). GIMES technology is not very recent invention, it is successfully running for over thirty years. In gas insulated medium voltage switchgear, vacuum technology is used as interrupting purpose and SF6 gas is used as insulation material. Although for both interruption and insulation, SF6 gas is used in many medium voltage GIS system. But for such equipments rated SF6 gas pressures are different for interruption and insulation. SF6 gas pressure for insulating purpose is generally kept below 2.5 bar whereas SF6 gas pressure for interrupting purpose is ranged from 5 bar to 7 bar. As vacuum technology is not available for high voltage, so for GIS or gas insulated switchgear system above 72.5 KV, only SF6 is used both for interruption medium and insulation. There are different types of gas insulated metal enclosed switchgears available depending upon their constructional feature.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what are inductive and capacitive voltage transformers.what are their applications

2006


What is the real function of reverse power relay in generator panel while syncronising?

2300


Explain the advantages and disadvantages of thermal power plant?

1141


How each of the following losses occur in d.c machines (i) copper (2)core (3) windage (4)friction please help me

2085


how does a shunt reactor maintains the bus voltage???

2124


1.what is the reason for transformer and lightning arrester blast in 33kv system

3147


Dear all: Recently we got a question about Interface between PMS and SAP-PM.once we got a update message from PMS.we should set the deletional flag for functional location in SAP system.Is there any FM or BAPI to use?There are only functional location create and change provided by SAP. Best regards!

2139


How to calculate cable rating for 3 phase supply?

2247


what is counter poise conductors

2210


Where voltage are high and current to be interrupted is low the breaker preferred is:

2345


EXPLAIN METOD OF IMAGE OF TRANSMISSION LINE/ WHAT ARE ITS PRACTICAL APPLICATION?

1945


What is the rating of circuit breaker needed for 300 KVA load in 33 KV supply line in a transformer of 33 KV / 415 Volt ?

1820


Which level of the Transformer oil got dielectric strengh? And why?

2303


IN dc capacitive reactance is??

1451


what are the difference between PLC and embedded

2186