What do you mean by linear and bilateral network?
Answer Posted / anita manikpuri
Linear - all elements and branches of circuit is obey ohm's law is called linear network.
Bilateral - bilateral means if you give some source voltage and gain some output and then you use this output voltage in form of source voltage then you gain some output , it is a value of initial source voltage. It means both are equal and current independent.
| Is This Answer Correct ? | 3 Yes | 1 No |
Post New Answer View All Answers
Name the component u would expect to find in a switchgear assembly?
what are the applications of transistors with low dc gain, high dc gain and medium dc gain( beta)?
A double circuit with dog conductor 66KV Transmission line from wind farm evacuation to feeding substation having capacity of 25MW for transmission. Can same transmission network be considered for further expansion of Power & how much in MW. If we need to expand next 10-15 MW more will there any augmentation is required in transmission network? Kindly reply asap.
on a three-winding transformer relationship delta-delta-star, on third winding why the relationship is a star? what are the advantages and disadvantages? Thank you and please help
What is the significance of integral controller and derivative controller in a pid controller?
WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.
i want to apper for apgenco or aptransco or related can any one sugest me where can i get previous papers of thouse exams
what is transient enclosure vltage , very fast transients, very fast transient over voltages
give some advantages and disadvantages of combiniing the session, presentation, and application layer in the osi model into one single application layer in the internet model
what happen when power factor of 2 parallely operated transformer become equle?
In case of HV test on medium voltage cables, BS is asking for 4 U0 where as IEC is asking for 3.5 U0. Can any one advise me how this 3.5 times or 4 times U0 is derived?
what is the meaning of WYE and DELTA in Electric meter?
Explain the laying procedure and laying depth of submarine/subsea power cable for 220/400KV system? Also available cable diameter?
in dc suppy frequency is zero why? if dc frequency is zero how to exist dc transients and ac transients
why ss stablity limit is more transient stablity limit?