We have 11kV/110V three phase indoor potential transformer in 66/11kV Sub-station, where the failure of PT is frequently happening and the rating of the PT is 0.2 class accuracy, with primary star and seconday (two cores) star connected.
Some experts has suggested to not to connect the PT Primary neutral to the ground because when transformer neutal NCT connection is loose; the faulty current will flow through the PT primary neutral, resulting into failure of PT.
My question is: Is it necessary to remove the primary neutral connection of the PT from ground? if not, what would be the reason for failure of PT.
Please guide me.
Answer Posted / karthikeyan
hai mr.gokul,what kind of failure in pt,please tell me.i will clear this problem..,
regards,
karthikeyan
+919095206722 (whats app)
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
if we give 60 hz single phase supply to the transformer used in europe , than what will happen
what is the current setting for different relay protection for transformer .
can anybody sent me power grid questions. what subject should i prefer for preparation?
how to compare with Relay settings for HT< panels, RMU panel, and PSS CSS transformer?? 1) Load amps, 2)Tripping time, 3) CT ratio, 4)Cable size 5) Transformer KVA rating 6) transformer full load amps
If a 3 phase induction motor is in off condition in the conveyor and rotor of the motor keeps moving with the conveyor than the resistance of windings of motor varies. why is it so ??
What is vaccum currcuit breaker.define with cause and where be use it device?
Dear all, I want to use Induction motor to open and close a 1 ton door. How much power do I need. Thanks
can we make a electric generator,which can not use any type of fuel,air,solar,gas,thermal,coal,petrol,etc and able to produce electrical energy (or self electricity generating generator)
how to calculate micom relay earth falt time and current sertting
Is better to supply the voltage for static exciter from the auxiliary power source or from the SG terminals? And why?
what will happen if i connect 12 volt battery with 24 volt battery charger.
What is the loss of power of transformer 220kv/33kv,63/80mva of % imp12.05 at 80%load
Please send 110 kv sb station full single line drawing(sld)
What are the main advantages of generalized error co-efficients?
dear all i am kumara now current working in electrical designing of control and relay panel i want learn some substaion design then any book are available. pls mention name and authour