an amazing situation was faced when an alive distribution panel with 415 volts and carrying almost 200Amps has become short and this metal cubical showing 220 volts against neutral and earth. to redress any confusion i checked the panel with help of single 200watts test lamp which also glowing with max.intensity b/w neutral & metal body of DB. amazing situation is that i hold the DB firmly more than once with necked foot means without insulated shoes but not received any electrical shock. whereas our all running gen sets neutral points also proper grounded and this short DB was completely earthed , this is beyond my understanding . any body explain how is it possible . our running gen set neutral also grounded firmly

Answer Posted / k.prakashchandra

Measure voltage between neutral and phases , it appears that neutral is connected to a phase , being isolated

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the selection process of breakers. Can any one please give a formulation on same?

1689


How to do cable earhing? whether by grounding Armour to ground or by running extra G.I wire along with cable? which one is preferred mostly amoung them? If the second one is more preferable how many GI wires to be run along with cable (1 or 2)?

1597


what is the disadvantages of common earthing for AC and DC equipment? (i am talking about inverter control room and inverter duty transformer earthing is common...?)

1189


what are the tests comes under the type test, what tests comes under routine tests.

1037


What are the advantages and disadvantages of the ac motors?

626






Hi My dear all Friends, There is a question regarding HVAC Engineering and widely used in Power Projects. Question- What is the diffrence Between REF, SEF and Differential Protection....???? Where REF - Restricted Earth Fault SEF - Senstive Earth Fault.

1722


explain transformer ct connection?

1619


How dia computation perfomed in cold rolling mills .

2599


Define peak overshoot.

799


can we use engine degreaser for electrical motors?

1303


What is the relationship between voltage,current & frequency?

1271


why all the feeders are designed in a particular manner ... is there any reason for that???

1504


what is the calculation formula for motor starting torque,running torque, running torque.

1228


How calculated single phase induction motor req. Capacitor?

1126


dg earth connect only in the amf panel or not why

1606