Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the purpose of a process loop? What is the
controllers responsibily?

Answer Posted / jadhavamit

The above question answer is explained by an example-
suppose we have to control the temperature of the water from "Heat Exchanger", for these we required a following instruments-
Temperature Transmitter=The transmitter sense the temperature of the boiler and convert these signal to standard signal 4-20 mAh.
Temperature Indicator and controller= The indicator use in the process has a facility of setting a SP(set point) for the desire process, these indicator with its inbuilt technology find out weather to increase the flow of steam or decrease the flow of steam. these condition depend on the logic E(error)=SP(set point)-PV(process variable).

suppose the output water has to maintain the temperature 200 degree cent. these is the SP to the controller.The controller will receive the signal from the temperature transmitter which is process variable(PV) and compare it with the SP i.e. let x be the PV(process value) then,
E=SP-PV
E=200-x
let x=150
then E=200-150
E=50
the value indicate that the inlet flow of the water should be OFF so that the outlet water temperature will reach to SP.

Note- Positive value OFF the inlet flow.
Negative value ON the inlet flow.

Temperature converter(I to P converter)= The signal send by the controller logically is converted into pneumatic by I to P converter with standard signal 3-15psi.
i.e. 3psi =4mAh &
15psi=20mAh respectively.

Valve= The valve can be air to open or air to close depend on the site selection and safety aspect.

*The controller responsibility is to maintain the process in SP and take the proper decision.
*Beside these was short or easy process so we can control it manually but when there is a large process parameter or it is not possible for a human to pay attention or also in hazardous area then at these place the controller play a vital roll in industries.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Percentage losses in power generation?

2992


what is working process of star delta controlling circuit ?

1880


armature winding of dc machine produce alternating emf then it convert in to dc by using commutator.But only we consider armature resistance why don't we consider inductive reactane effect?

2071


how to determine ct ratio in ht vcb?

1848


what is the difference between droop mode and ischnorous mode in thermal powerplant?

2662


What is miller crystal oscillator? Explain its operation?

1113


A d.c. Shunt motor is found suitable to drive fans because they require?

1320


what is the difference between switchgear and circuit breakers and is there any difference between outdoor and indoor switchgear and circuit breakers , and how would you differentiate between switch yard and substation and grid station . thanks

2226


which type of motor is used in automatic swing gate

2012


Starting times for soft starter & power factor is thier any standard or datas available in manufactures list. Kindly suggest.

1935


how circuit breaker work.. what is the operations taking place inside a circuit breaker when an overcurrent occurs... is it similar to fuse?

2071


What Normal(Tangent) towers and Tension(Cut-point) Towers?

6220


what is the ms flat constant for calculating earth mat design calculation?

2518


What are the main parts of central chiller plant? Explain the function of each stage.

4804


y we use neutral,all r told its used to for closed path..k its a just used to closed path,in a transmission line y we put same conductor used n both phase and neutral..if we use less than phase conductor in neutral mean we ll reduce cost its right r wrong..if we use mean any problem occur in transmission line..

1990