Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Hello,l am complete dip and i was working maintance in ht dep again i study b.e completed again one year exp in ht totally two year i am ealigble in c license

Answer Posted / sk ajamat ali

All BE AND btech cerificate is equivalent to B licence
So no need to apply for c or B Licence
And for A licence you need expirience in HT transmission line work that to under a A class contractor

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Determine a suitable number of slors and conductors per slot for the starter 1 winding of a 3 phase, 3300 V. SO Hz 300 rpm alternator. The diameter is 2.3 m

2764


How does a tertiary winding filter harmonic(espcially 3rd one) from entering into load system?

1750


can anyone please help me to find the rupturing or breaking capacity in KA of circuit breaker (MCCB,VCB,ACB etc) of HT and LT side of a distribution transformer...please help with detailed step by step answer...thank you

1938


-How do you select cable size for a given load at a given distance from source of supply. How do you find voltage drop.

1743


how to test reverse power trip?

4411


How could a garment factory benefit from renewable energy

2707


State the methods of improving power factor?

1091


what is the reason the main breaker is trip during the motor is running? (some time the breaker is not trip)

1731


what will be the effect if you were using different brands of outlets?

1866


sourse is 66 KV / 350 MVA, transfarmer is 1000 KVA 6.6 / 0.415 kv, iF fault is 28.75 MVA on 0.415 KV Bus then calculat the Transfarmer Impidance

2051


wat is the current produced in a 5000v megger? when the positive and negetive terminals are touched on our body get s shock?

1868


explain different losses in a transformer.

1056


sir, what is the importance of Fault MVA. how to calculate fault mva of 33kv substation connected by 6.5 km line(single circuit with equal spacing) with 110/11kv transformer in 110kv susbstation.the fault mva on 11 kv bus in 110kv susbstation is 208mva.

2878


what is the maximum permissible limit value of leakage current and leakage counter reading to replace lightining arrester?

5073


Why neutral is not used in three phases dol starter

1879