Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the diff. b/w balanced and unbalanced load..?

Answer Posted / rahul bathri

The load circuits Delta with so far were balance Ed circuit s. In balance Ed polyphase circuit the impedance s in different phases are same .now we will consider the methods of solving unbalanced Delta connected and star- connect load circuits I.e the circuits consisting of impedance in one or more phase different from those in other phase .

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the typical enclosure type used for Indoor switchgear / Outdoor switchgear Units? - In Onshore / offshore Units?

1041


Please define ampere?

1170


What will happen if a dc source is given to a tubelight. Will it work or wont it work....

2042


How to convert 2 phase to 3 phase electricpower in induction moter?

2163


are there rmu for 3 transformer?

1943


1.what is difference in maintain Hz again Hz in USA ? 2.how to calculate the battery AH? 3.why are yearly maintained in transformer how many tests in required?

2816


WHY BLADE & JOW OF ISOLETOR IN SUBSTATION?

5138


Can we use shunt trip coil instead of trip coil with protection relay for protection?

1781


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2522


If we need 4c× 50mm sq cable but it's not available so we can pull 4c×25mm sq two cables?

1464


in india per day how much power is generated including all power station

2025


how to measure dc earth leakage current?

3243


before synchronizing an alternator,power factor is leading ,why?

1633


Why syn. Generators are used for the production of electricity?

1205


-What should be minimum value of insulation resistance and maximum value of earth resistance at any electrical instillation and what is method of testing the same.

2140