Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What will happen if the field of synchronous generator is
removed when it is in operation with no load?

Answer Posted / krishna

If it is connected to network ( grid ) with the prime mover
still running ,it may work as induction generator .othwerwise it will work AS INDUCTION MOTOR.

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why frame of the motor is specified?. If we mention KW and voltage level,automatically frame is decided or separately frame is compulsory to mention?.

1779


Can XLPE/SWB/PVC (P3) 7C X 2.5mm2 be replaced by Can XLPE/SWB/PVC (P2) 7C X 2.5mm2??? P3 vs P2

1913


What are IR values and what it should be for coil and for insulator

3046


What is the method of estamating of cable, CB,MCB ?

2225


Explain marx circuit.

1395


What is kirchoff ’s current law (kcl)?

1139


solor panels arrange some angle,panel is flat fitted energy was produced or not why?

1966


what a function diesel generetaor turbo charger & turbo charger is more heated explain reason ?

2305


block diagram of 2 ups system connected in parallel mode?

2122


how do we calculate length of starting time and repeated starting of a direct online starter?

2033


Why do not we prefer non conventional sources of energy to conventional sources?

1247


how to calculate transformer load?

2536


Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?

2034


Post possible questions for Power Factor Panel FAT / SAT

1457


What is true sine wave or pure sine wave inverter?? Is it sine wave or step wave?? If it is step wave, waves with how much step is considered as pure sine wave? Is it possible to produce pure sinewave using power electronics?

1923