Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

if we supply DC power to AC transformer then what its result?

Answer Posted / mintuk1@gmail.com

We know that transformer coil is highly inductive and low resistive.so if we apply the dc voltage in primary coil then a heavy current flows to the coil .that causes a heating effect produce .by this heating transformer coil may burn .for this reason we do not apply dc on transformer coil .

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the Pickup/drop off ratio in BCPU relays

4576


5.WHICH TYPE WELDING PROCESSES USES NON CONSUMABLE ELECTRODE.........

2029


What are the special cables required for explosion proof wiring?

16571


Why do we use copper cable for HT Supply and why not Aluminium?

1959


1.what is the difference between transformer differential and busbar differential.2)why we are using 2 slope for trafo diif and 1 slope for busbar diff.3)what is the purpose of metrosil and stabilizing resistor in high impedance relay circuit.4)how metrosil reduce the peak volage.5)what is the funtion of stabilizing resistor

4796


i am going to give the JSEB,RANCHI exam for power plant,so i need some samples of papers related to that,so please send me these papers by my mail id.

3429


I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.

2229


Is there any relevant technique to produce power from light and heat energy of the sun simultaneosly from same rays of light?

1824


when we design electrical schemes of 11/.415kv distribution..wen and were should we show the relays??what is the function of it?for example..we place EFR Relay CT between transformer neutral link and transformer earth.Like this what are the other type of relays we should use?why?where?Explain please..Thank you

1744


how to Select Lighting arrester? What r the parameters to be considered for the selection of Lighting arrester ?

1677


how to calculate the surge level of surge suppressors related to the SF6 cicuit breakers?

1929


how can we select the appropriate VCB ?

2234


why we use two slope(differential & restraining) in differential relay.but in busbar protection differential we are using only one slope?please explain

2194


what are the 4 rules to start the motor?

2047


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The slip when motor stalls is A 1 B 0 C 13.33% D 10.33%

1850