ORA-01545: rollback segment 'string' specified not available
Answer Posted / guest
Cause: Either: 1) An attempt was made to bring a rollback
segment online that is unavailable during startup; for
example, the rollback segment is in an offline tablespace.
2) An attempt was made to bring a rollback segment online
that is already online. This is because the rollback segment
is specified twice in the ROLLBACK_SEGMENTS parameter in the
initialization parameter file or the rollback segment is
already online by another instance. 3) An attempt was made
to drop a rollback segment that is currently online. 4) An
attempt was made to alter a rollback segment that is
currently online to use unlimited extents. 5) An attempt was
made to online a rollback segment that is corrupted. This is
because the rollback is specified in
_corrupted_rollback_segments parameter in initialization
parameter file.
Action: Either: 1) Make the rollback segment available; for
example, bring an offline tablespace online. 2) Remove the
name from the ROLLBACK_SEGMENTS parameter if the name is a
duplicate or if another instance has already acquired the
rollback segment. 3) Bring the rollback segment offline
first. This may involve waiting for the active transactions
to finish, or, if the rollback segment needs recovery,
discover which errors are holding up the rolling back of the
transactions and take appropriate actions. 4) Same as 3). 5)
Remove the name from the _corrupted_rollback_segments parameter.
Please add more information about this Error
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How to resolve QSM-01108 error. I have no OR conditions in my query, but do have 9 IN conditions. The error says the max limit is 2 while I have 257 number of disjuncts. However, if I remove even a single IN condition, the query is rewritten. I cannot change my query. How can I resolve this issue?
ORA-16626: failed to enable specified object
RMAN-05017: no copy of datafile number found to recover
IMP-00070: Lob definitions in dump file are inconsistent with database.
if the lengths of two wires are same and the area of cross sections is 4:7 then what will be the ratio of current passing through these wires
IMP-00060: Warning: Skipping table "string"."string" because object type "string"."string" does not exist or has different identifier
ORA-26082: load of overlapping segments on table string.string is not allowed
NZE-28868: Peer certificate chain check failed.
ORA-26030: index string.string had string partitions made unusable due to:
ORA-26029: index string.string partition string initially in unusable state
ORA-26079: file "string" is not part of table string.string
invalid quantity specification negative quantity are not allowed for this item please check this item definition quantity
IMG-02003: 2FF03 - incorrect color histogram feature specification
[ERROR] [main 11:01:20] (JCLLoggerAdapter.java:error:454) Unsuccessful: alter table user.CEN_USER_MASTER add constraint FKF4EDEDC3D0BAAE75 foreign key (ROLE_ID) references user.CEN_ROLE_MASTER [ERROR] [main 11:01:20] (JCLLoggerAdapter.java:error:454) ORA-02275: such a referential constraint already exists in the table
ORA-16627: No standby databases support the overall protection mode.