What is the working of SCM CT
or purpose in genrator ?
Answer Posted / hitesh gavaniya
SCM CT is a normal ct , which is connected with generator output terminal , and CT's Terminal are connected with AVR . Depending on the load on the generator , the current increases & Accordingly SCM CT gives the input to the AVR so as to develop the required field to generate the same load without any dip in the voltage.
| Is This Answer Correct ? | 2 Yes | 5 No |
Post New Answer View All Answers
ROC converges if pole and zero lies inside a) origin b) z=1 c) pole d) zero ? Explanation please? if ROC does not converges then?
What are the raitings of Mcb,mccb and Acb in detail ??
What is the Basic Difference bitween Long Shunt Connection and Short Shunt Connection in DC Generator?
what is allowable ac mixing in dc
what is laser diodes?
Explain in brief description about the operation of DG sets.
While performing stability test of differintial cts how to know the voltage and current on both side of the transformer?
Why sometime AVR and sometime Booster coil is used in Alternator? what is the diferance between AVR & Booster coil due to which they are selected
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
If I have Energy Meter Ratio as 100:5 & Also I have CT Ratio as 50:5 then what will be my multiplying Factor(M.F.)
How do apply electrical 'c'license......pls advice
How to calculate per unit impedance of transformer?
what happen ehen synchronisation is done at below rated speed
how to calculate transformer turn primary & secondary side 11kv to 420v
What is a single phase autotransformer?