What are Line losses and how can be it minimized/controlled.?
Answer Posted / abc
There typically two types of losses in line T&D.
1. Technical Losses
The technical losses are due to energy dissipated in the conductors, equipment used for transmission line, transformer, subtransmission line and distribution line and magnetic losses in transformers.
Technical losses are normally 22.5%, and directly depend on the network characteristics and the mode of operation.
The major amount of losses in a power system is in primary and secondary distribution lines. While transmission and sub-transmission lines account for only about 30% of the total losses. Therefore the primary and secondary distribution systems must be properly planned to ensure within limits.
The unexpected load increase was reflected in the increase of technical losses above the normal level
Losses are inherent to the distribution of electricity and cannot be eliminated.
There are two Type of Technical Losses.
1. Permanent / Fixed Technical losses
Fixed losses do not vary according to current. These losses take the form of heat and noise and occur as long as a transformer is energized
Between 1/4 and 1/3 of technical losses on distribution networks are fixed losses. Fixed losses on a network can be influenced in the ways set out below
Corona Losses
Leakage Current Losses
Dielectric Losses
Open-circuit Losses
Losses caused by continuous load of measuring elements
Losses caused by continuous load of control elements
2. Variable Technical losses
Variable losses vary with the amount of electricity distributed and are, more precisely, proportional to the square of the current. Consequently, a 1% increase in current leads to an increase in losses of more than 1%.
Between 2/3 and 3/4 of technical (or physical) losses on distribution networks are variable Losses.
By increasing the cross sectional area of lines and cables for a given load, losses will fall. This leads to a direct trade-off between cost of losses and cost of capital expenditure. It has been suggested that optimal average utilization rate on a distribution network that considers the cost of losses in its design could be as low as 30 per cent.
Joule losses in lines in each voltage level
Impedance losses
Losses caused by contact resistance.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What does the a,b,c of 95a,95b,95c relays denotes?
I have c license but I don't know eligibility of Max Kilo Volts under the electrical licensing board.
Usage of flywheel diode in relays
why swinburnes test cannot be performed on series machines?explain
What are the electrical engineer roles and responsibilities in chemical plant?
i installed 100kva ups. what KVA genset they should provid in input side? plz any update formula or ans with reason.
what are the range of memory address in plc for L&T lx7 4A
How to select transmission line type (i.e. 11kv or 33kv) for new established industries
how freewheeling diode improves the powerfactor
describe the constructional features of an auto transformer and its principle operation
after how many spot we must chang secondry cable in portable spot welding gun?
which one is more efficient, torq, power & ecnomy with the same frame size AC motor / DC motor?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
How Can I calculate for the photometrics requirements for a street lighting? Data given are: 45 units of 6 meter light pole with 150 watts metal halide lamp, 220 volts and installed in a promenade area.
What is the difference between Encoder and Resolver?