how to find under ground cable fault ???
if our cable size is 95*4 then what will load capacity
with far mull

Answer Posted / gajendra

if we will try as cable resistance ya other Margare meter but in short cable condition always show Resistance. pleas tell me how we can find and what is correct answer

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

before transformer oil dielectric strenght tests are taken the oil should be allowed to settle to remove option 1 air bubbles 2 gasses 3 contamination 4 water

1189


How many lightning arrestors to be installed on 50MX60MX10M building and is there any formular for that?

1475


In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.

1716


There are different classes of protections in power plants.class a,b,c are clear..is there any class d and e r there..and elaborate class b protection.

1636


What is super thermal power plant? and how it will differ from normal thermal power plant

1843






how to calculate the surge level of surge suppressors related to the SF6 cicuit breakers?

1557


while doing high voltage test on 11kv/433 distribution transformer why we only give 28 kv on hv side and 3kv on lv side for power transformers what is the value what factors it depends

2377


What is the effect of solar radiation on the design of an Isolated Phase Busduct?

1874


What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer

1904


How to set the relay,,??

1633


where is core-type and shell-type construction suitable for transformers ?

1652


I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?

1786


What type interview questions ask in Electrical technicians

1266


What is a commutator?

616


How relay works, reverse relay, master relay, os relay, earth fault relay and what is its setting point