what is proportional &
what is proportional band
Answer Posted / morsli
Hi the gain equal the variation of the out put variable devide the variation of the in put variation.
the proportionel BAND is the reverse of gain .
PB =1/k*100%
In the controller we find the proportional band with percent %
If we want to adjust the correct value of proportional band for the proportional controller ,we have to decrease the proportional band ,till we have cycling in process ,means out put of controller ,and the correct value for operationg process is the double of the cretical or cycling proportional band.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what is function of SCADA , and how is it work, explain with difination
hello friends, can you please send me the model paper or question paper to be prepared for hpcl examinations????????? You can mail me at rahim_here@yahoo.com waiting for your reply........... help me .. plz.....
installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,
Why is the orifice tab provided?
why we should maintain neutral earth voltage below 1V while calibration? why cant it be 1.2V or 2V
how to tune siemens sipart electro pneumatic positioner..plz tel me..
which type of filter gives the constant phase characteristics?
what is sliding spool valves?
TECHNICAL/ARTITUDE
What is motion balance principle?
the output of the common trasmitter protocol in qatar gas are the following
what is the difference between active & reactive power?
what is orfics working in main steam line. is it increase pressure, velocity of steam flow and dicrease steam flow rate. or any other
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.