what is electricial and mechnical interlock.
Answer Posted / vinoth . k
Electrical Interlock- It is the interlocking of two
incoming power supply by using electrical equipments like
relays.
Consider we have two power supply viz, EB and DG supply.If
EB supply cut,DG will run and viceversa.By mistake whether
both EB and DG supply is ON, it will make hazardous action
to our panels.At that time that relay will sense and make
NO,NC changes and allow only one supply pass through our
loads.
Mechanical Interlock- It is the interlock between two power
supply by using Key System.
There are two locks and one key. If we want to switch ON EB
power, first we have to lock DG power and remove the key
from DG lock and then we can switch ON EB supply and
viceversa.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what happen if the supply is given to the stator of the 3phase induction motor with out assembling the rotor ?
Is it required to use Automatic transfer Switch in L&T panel board if we use AMF panel with DG set? How the single line diagram will be? Please forward the material to sreenu_207@yahoo.co.in
How to connect the chemical earthing and complete process tell me plz
how to calulate short circuit current for the following: 1.cable connecting 11KV of 22KV/11KV transformer to 11Kv of 11KV/415V transformer 2.what cable size should i use.
What information we need to prepare relay coordination chart
Please brief what is sinewave
54 Comments Alok and Bhanu play the following min-max game. Given the expression N = 38 + X*(Y – Z) where X, Y and Z are variables representing single digits (0 to 9), Alok would like to maximize N while Bhanu would like to minimize it. Towards this end, Alok chooses a single digit number and Bhanu substitutes this for a variable of her choice (X, Y or Z). Alok then chooses the next value and Bhanu, the variable to substitute the value. Finally Alok proposes the value for the remaining variable. Assuming both play to their optimal strategies, the value of N at the end of the game would be?
In HI POT test what is reason for applying the AC VOLTS and DC VOLTS in different applications what is the nessesity for this ?
What are the limitations of Kirchoff's laws?
What are conduct on the testing in cf in ur site?
How can calculate the rating of a servo stabilizer for given a specific load
What will be advantage if we put some load in neutral of grounded star transformer & loadshortcircuit current,rated current of cable & MCB with example?
I want to ask that is there any relation between current denesity of copper and material purity. also is ther any standard which defines the standard current denesity of material.
In what cases (circumstances)we should apply P controller, PD controller, PI controller & PID controller ?
what is the VA(Volt-amphere)? define with calculation?