Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is Beer Lambert low ?

Answer Posted / sukanya

The absorbance of light is directly proportional to the thickness of the media through which the light is being transmitted multiplied by the concentration of absorbing chromophore; that is,
A = εbc where A is the absorbance, ε is the molar extinction coefficient, b is the thickness of the solution, and c is the concentration.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the principle of Thermal conductivity detector and FID?

2723


If vendor having more imp than monograph then how to proceed? and how to set spec?

919


how a particular wavelength can be different for a particular compund while analysing by uv and by HPLC.

2283


if content uniformity passing but dissolution varrying then what is next step?

866


Why six unit used for precision?

1339


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1965


is it necessary to do HPLC calibration at wavelength 315nm if we are doing analysis at this wavelangth

2166


why we use a particular hplc column for a particular compound give reasons?please

2746


How to set analytical specification for combination products?

815


What is diffrence between extractable volume and deliverable volume? Answer pls

4556


pharma industries oriented

2230


How to determine the EDTA content by potentiometry titration in Ceftriaxine sodium

2535


what is difference in ods I ods II is this is realy from sorbent / packing characteristics or from other means

1966


how many types of balance calibration test?

2295


why are measure gas flow " ml " in Gas chromatography

1650