Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Residual Voltage & Residual Current?

Answer Posted / mano

the induced EMF when the field current is zero is known as residual voltage

Is This Answer Correct ?    15 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

which type of amplifiers are used in multimete?

2145


does any one know where we can purchase insulation oil for high voltage oil filled cables

2278


It is desired to flood light the front of a building 42 meters wide and 16 meters hig.Projectors of 30 degree beam spread and 1000 watt lamps giving 20 lumen/watt are availabl.If the desired level of illumination is 75 lumen/m and show a suitable scheme.Assume the cofficient of utilization, deprecitation factor and waste light factor are 0.4, 13 and 1.2 respectively.

3807


What is d main advantage of using double circuit 3 phase transmission ?

1880


being an electrical engineer why you wanna come into software i have an very good academics what answer i have to give

1863


Why we use duplex coil and hook switch in telephone system?

4980


What is the difference between single point and double point bonding. please kindly detail about bonding of cables.

2387


what is the earth current,reverse power,electrical trip generator short circuit,low voltage, high voltage please discribe me

2061


Dear sir, In our plant have Station Transformer having capacity,i want to know, why LV side 40 - 40MVA is given? & how we can get 6.3 KV supply from tertiary(i.e. Open delta connection), Vector Group YNyn0 - yn0 +d MVA Rating 80MVA / 40 - 40MVA + 26.7MVA Voltage rating 420 (Tap range +6,to -10)81.25% /11.5KV - 11.5KV +6.3KV

2125


Which of the following alternatives will be cheaper (1) A 100 h.p AC, 3-phase motor (2) Four motors of 25 h.p each (3) Five motors of 20 h.p each (4) 10 motors of 10 h.p each explain

2937


Difference between rating factor of cable and derating factor of cable?

1592


which type of effect of turbine and generator reverse power protection ?

4147


While performing stability test of differintial cts how to know the voltage and current on both side of the transformer?

3496


how we can calculate power factor in single phase & three phase ?thank u

1958


what is effect of length of air gap on performance of dc motor and generator?

1816