Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why salicylic acid not use for dissolution.

Answer Posted / sagar bakade

Salicylic acid tablets were non-disintegrating and uncoated tablets but practically uncoated and non-disintegrating formulations are very rare, so there was no requirement for the calibration the dissolution apparatus with the non disintegrating tablets.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

1908


HI,I CLEARED BOB CLERK EXAM. MY INTERVIEW WILL BE ON 9TH OCTOBER,2010.PLEASE SEND ME INTERVIEW QUESTIONS AND ANSWERS. THANK YOU.

2249


if content uniformity passing but dissolution varrying then what is next step?

878


Why potassium dichromate is used in calibration of uv?

1988


what is turbidimetric titration?Give 2 examples.

2670


i want model written test paper for the post of analyst in IOCL(indian oil corporation ltd) any one pls help me

2735


Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1820


Did anybody have method for acetyl cysteine effervescnce tablet

2254


if identification threshold crosses the limits then what next step?

864


how to calculate elemental impurities?

1034


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3540


What is delay volume?

1394


for which product require to do content uniformity? what is limit of cu?

819


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

2224


In the isomers,enantiomers give the only physical properties present such that no chemical properties present.

2222