Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

A synchronous machines has higher capacity for
(1) Leading power factor (2) Lagging power factor
(3) Does not depend upon the power factor of machine (4) None of
the above

Answer Posted / ashwini kumar

Leading power factor

Is This Answer Correct ?    24 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what are the effects when a salient pole alternator is run at high speed like 3000 r.p.m?

2381


List the characteristics of filter?

997


I have 4 busbar of 1000 ampere. we use 4 busbar to make 4000 ampere in one phase.my problem is that when we applied 60% load on that then busbar produced high noise.what is the reason of that and how can i minimize that noise.

1652


I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?

1687


Dear sir, By which formula u can calculate for a particular kv line there is a range of mw.

2067


132/6.6𝚔𝚟 𝚝𝚛𝚊𝚗𝚜𝚏𝚘𝚛𝚖𝚎𝚛 𝚗𝚎𝚞𝚝𝚛𝚊𝚕 𝚑𝚊𝚜 𝚘𝚗𝚎 𝚎𝚊𝚛𝚝𝚑 𝚙𝚒𝚝 𝚍𝚎𝚍𝚒𝚌𝚊𝚝𝚎𝚍. 𝙸'𝚟𝚎 𝚊𝚗𝚘𝚝𝚑𝚎𝚛 𝚝𝚛𝚊𝚗𝚜𝚏𝚘𝚛𝚖𝚎𝚛 𝚘𝚏 6.6𝚔𝚟/415𝚟 𝚌𝚊𝚗 𝙸 𝚌𝚘𝚗𝚗𝚎𝚌𝚝 𝚗𝚎𝚞𝚝𝚛𝚊𝚕 𝚝𝚘 𝚜𝚊𝚖𝚎 𝚎𝚊𝚛𝚝𝚑 𝚙𝚒𝚝 𝚊𝚜 𝚘𝚏 13/6.𝚔𝚟 𝚝𝚛𝚊𝚗𝚜𝚏𝚘𝚛𝚖𝚎𝚛?? 𝙸𝚏 𝙽𝚘.. 𝚃𝚑𝚎𝚗 𝚠𝚑𝚢??

928


what is the main difference between power devices and signal devices

2135


Name two types of electrical analogous for mechanical system.

1153


Draw the single line diagram of the power station?

1022


What are the essential characteristics of signal flow graphs?

1043


What is a commutator?

990


what will be the maximum winding temperature of 6.6kv HT motor 450kw, Full load current 49A. 50Hz Frequency.

3172


What is meant by cold loop test in instrument

2549


how choose conductor&depending upon load

1835


Sir, plz tell me how droop setting is done in parellel operation od DG set ? please give practical example ?

2090