What is the difference between class0.1 and class 0.1s
accuracy of current transformers
Answer Posted / vishwateja bodla
Current transformers with accuracy 0.1 shows reading within a composite error of 0.1% but when loaded above 50 to 60% in case of loading from 10 to 50 % error is more which is not acceptable by tarrif( number of units consumed) measure because of which power supply companies gets losses when coming to large consumers like factories so they recommend 0.1s class cts which deviate less than class 0.1 when loaded at 10 to 50%
Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What are root loci?
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.
How to calculate Grid rotor resistance(GRR) losses in slip ring induction motor?
can we synchronize star system generators with delta system generators?
what is the role and fuction of automatic transfer switch in rotary ups
Who are the manufactures those manufacturing 3Cx2.5sqmm FRLS cables. I heard about FRLS technology adopted only in wires useful for wirings
What is the best thing to protect the motor from running over full current. CT or O/L or pressure transducer at the given pressure rating
help me with the question that might be ask on the interview for technical position
can we conduct the swineburne's test on a dc series motor? why?
what is the relationship between current&voltage in practical purpose ?
what is the difference between the voltage of 5 volts capacitor and and 5volts battery?
We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks
What are the two segments of nyquist contour.
which is the most advanced form of SF6 BREAKER?Can we use other gases to quench the arc?
In MEP Services what are parts of STP and what are there function?